Off-Register.

Off-register results in an obvious misalignment of the O-ring “halves” (see Figure 68). Off-register results from a lateral shift of one of the mold cavity plates in relation to its mating plate. (For maximum acceptable off-register, see Table 32.)

 

QUALITY ASSURANCE MAIN PAGE

“Off-register results in an obvious misalignment of the O-ring ‘halves.’”

 


Figure 68


Table 32